Choose a transformer and fuse that will supply 12 V. to a 1.5 ohm load. The primary voltage will be 117 V.
- Calculate secondary current.
- Calculate primary current.
- Go to www.mouser.com
- Search for transformer
- In the Power section, click Power Transformers
- In the Product Category box, click Power Transformers
- Click Apply Filters
- Scroll down to Power Transformers, Single Secondary.
- Click Page 1,622
- Choose the least expensive transformer that will do the
job. Mouser Part Number: ______________________, Cost for one:
______________
- Search for fuse
- In the Circuit Protection section, click Fuses
- In the Product Category box, click 5mm x 20mm fast acting
- Click Apply Filters
- Choose a 250 V. axial fuse that will do the job. Mouser Part Number: __________________________, Cost for one: ______________
|